Specifikacija
Vrsta | Ocena AC-3(A). operativni tok v AC-3(A) | Največja moč 3-faznih motorjev v | Delovanje pogostost (čas/ura) | Električni lifeAC-3 x104 | Mehanski življenje x104 | ||||||
kategorija AC-3(kW) | AC-3 | ||||||||||
220V 230V | 380V 400V | 415V | 440V | 500 V | 660V | 1000 V | |||||
690V | |||||||||||
JLC1-F115 | 115 | 30 | 55 | 59 | 59 | 75 | 80 | 65 | 1200 | 120 | 1000 |
JLC1-F1154 | 115 | 30 | 55 | 59 | 59 | 75 | 80 | 65 | 1200 | 120 | 1000 |
JLC1-F150 | 150 | 40 | 75 | 80 | 80 | 90 | 100 | 65 | 1200 | 120 | 1000 |
JLC1-F1504 | 150 | 40 | 75 | 80 | 80 | 90 | 100 | 65 | 1200 | 120 | 1000 |
JLC1-F185 | 185 | 55 | 90 | 100 | 100 | 110 | 110 | 100 | 600 | 100 | 600 |
JLC1-F1854 | 185 | 55 | 90 | 100 | 100 | 110 | 110 | 100 | 600 | 100 | 600 |
JLC1-F225 | 225 | 63 | 110 | 110 | 110 | 130 | 129 | 100 | 600 | 100 | 600 |
JLC1-F2254 | 225 | 63 | 110 | 110 | 110 | 130 | 129 | 100 | 600 | 100 | 600 |
JLC1-F265 | 265 | 75 | 132 | 140 | 140 | 160 | 160 | 147 | 600 | 80 | 600 |
JLC1-F2654 | 265 | 75 | 132 | 140 | 140 | 160 | 160 | 147 | 600 | 80 | 600 |
JLC1-F330 | 330 | 100 | 160 | 180 | 200 | 200 | 220 | 160 | 600 | 80 | 600 |
JLC1-F3304 | 330 | 100 | 160 | 180 | 200 | 200 | 220 | 160 | 600 | 80 | 600 |
JLC1-F400 | 400 | 110 | 200 | 220 | 250 | 257 | 280 | 185 | 600 | 80 | 600 |
JLC1-F4004 | 400 | 110 | 200 | 220 | 250 | 257 | 280 | 185 | 600 | 80 | 600 |
JLC1-F500 | 500 | 147 | 250 | 280 | 295 | 355 | 330 | 315 | 600 | 80 | 600 |
JLC1-F5004 | 500 | 147 | 250 | 280 | 295 | 355 | 335 | 335 | 600 | 80 | 600 |
JLC1-F630 | 630 | 200 | 335 | 375 | 400 | 400 | 450 | 450 | 600 | 80 | 600 |
JLC1-F6304 | 630 | 200 | 335 | 375 | 400 | 400 | 450 | 450 | 600 | 80 | 600 |
JLC1-F780 | 780 | 220 | 400 | 425 | 425 | 450 | 470 | 450 | 600 | 80 | 600 |
JLC1-F7804 | 780 | 220 | 400 | 425 | 425 | 450 | 475 | 450 | 600 | 80 | 600 |
JLC1-F800 | 800 | 250 | 415 | 450 | 450 | 450 | 470 | 450 | 600 | 80 | 600 |
Oris in montažna dimenzija
JLC1- | a | b | b2 | c | f | G* | G min. | G maks. | G1 * | G1 min. | G1 maks. | J | L | M | P | Q | Q1 | S |
2P | 213 | 206 | 375 | 219 | 119 | 80 | 66 | 102 | 170 | 156 | 192 | 19.5 | 145 | 181 | 48 | 69 | 96 | 25 |
F400 3P | 213 | 206 | 375 | 219 | 119 | 80 | 66 | 102 | 170 | 156 | 192 | 19.5 | 145 | 181 | 48 | 43 | 74 | 25 |
4P | 261 | 206 | 375 | 219 | 119 | 80 | 66 | 150 | 170 | 156 | 240 | 67.5 | 145 | 181 | 48 | 43 | 74 | 25 |
2P | 233 | 238 | 400 | 232 | 141 | 80 | 66 | 120 | 170 | 156 | 210 | 39.5 | 146 | 208 | 55 | 76 | 102 | 30 |
F500 3P | 233 | 238 | 400 | 232 | 141 | 80 | 66 | 120 | 170 | 156 | 210 | 39.5 | 146 | 208 | 55 | 46 | 77 | 30 |
4P | 288 | 238 | 400 | 232 | 141 | 140 | 66 | 175 | 230 | 156 | 265 | 34.5 | 146 | 208 | 55 | 46 | 77 | 30 |
JLC1-F | a | G | G min. | G maks. | J1 | Q | Q1 | |
F630 | 2P | 309 | 180 | 100 | 195 | 68.5 | 102 | 127 |
F630, F800 | 3P | 309 | 180 | 100 | 195 | 68.5 | 60 | 89 |
F630 | 4P | 389 | 240 | 150 | 275 | 68.5 | 60 | 89 |
JLC1-F Bobbin AC kontaktorja JLC1-F
Proizvodni inženiring kontaktorjev:
1.Odličen material lupine
2. Bakreni del s kontaktno točko iz 85 % srebra
3. Standardna bakrena tuljava
4. Visokokakovosten magnet
Lepa embalažna škatla
Scenariji uporabe:
Običajno nameščen v razdelilni omarici na tleh, računalniškem centru, telekomunikacijski sobi, nadzorni sobi dvigala, sobi za kabelsko televizijo, nadzorni sobi stavbe, požarnem centru, industrijskem avtomatskem nadzornem območju, bolnišnični operacijski sobi, sobi za spremljanje in opremi distribucijske omarice z elektronsko medicinsko napravo .